EcoService OSEcoService OS

PV, HVAC and refrigeration diagnostic labs

One decision on screen at a time. Wrong turns get coached, not just marked. You do not finish until the root cause is confirmed and the repair is verified. Three labs are free — no account needed. The rest of the labs, lessons, exam banks and timed mocks are part of HVAC Technical Training — Paths A–D.

  • Interactive decision labs
  • Built by working technicians
  • Path-based verifiable certificate
  • Know which exam to book
  • Worldwide online

PV pathway lab previews

Residential HVAC Service & Diagnostics
~14 min
Free

Residential No-Cool — Split System Not Cooling

Homeowner says the air handler is blowing but the house has been getting warmer since yesterday afternoon.

Start the free lab →
Residential HVAC Service & Diagnostics
~15 min
Paths A–D

Residential No-Heat — Gas Furnace Short Cycling on Ignition

Homeowner reports intermittent no-heat. The furnace lights, runs for a few seconds, then shuts down and tries again.

Unlock with Paths A–D →
Residential HVAC Service & Diagnostics
~13 min
Paths A–D

Frozen Coil / Airflow Restriction

Homeowner says the system runs all day but barely cools, and the vents feel weak and cold-damp rather than cold and strong.

Unlock with Paths A–D →
Residential HVAC Service & Diagnostics
~14 min
Paths A–D

Residential Over- and Undercharge — Poor Cooling Call

Homeowner says the system runs all day and the house never gets below 78°F. Another contractor “topped it up” last month and it felt better for a week.

Unlock with Paths A–D →
Commercial Refrigeration / RAC
~12 min
Paths A–D

Superheat / Subcooling Decision

Walk-in cooler is running continuously and only reaching 42°F on a 35°F setpoint. Customer says it used to hold fine.

Unlock with Paths A–D →
Commercial Refrigeration / RAC
~14 min
Paths A–D

TXV Hunting — Temperature Swings

Walk-in cooler temperature keeps swinging — overshoots cold, then drifts warm, never settles. Customer says they already added charge and it did not help.

Unlock with Paths A–D →
Commercial Refrigeration / RAC
~14 min
Paths A–D

Condenser / High Head — Walk-in Cutting Out on High Pressure

Walk-in cooler is running warm and the compressor keeps cutting out on the high-pressure control. The site contact is convinced it just needs gas.

Unlock with Paths A–D →
Commercial Refrigeration / RAC
~15 min
Paths A–D

Rack — One Circuit Down (Case Group Warm)

Supermarket rack: one case group is running warm while the other five circuits hold temperature. The night manager wants gas added to the rack; someone on shift has suggested shutting the whole rack down to see if it is that one.

Unlock with Paths A–D →
Residential HVAC
~12 min
Paths A–D

A2L Safe-Handling Decision (R-454B)

A no-cool call at a small mixed site. One new split system is on an A2L refrigerant, the two older units are legacy A1. You must set safe working practice before you open anything.

Unlock with Paths A–D →
Commercial Refrigeration / RAC
~15 min
Free

Walk-in Cooler Not Holding Temperature

Walk-in cooler is running but product temperature is rising. Box is at 48°F, setpoint 35°F.

Start the free lab →
Commercial Refrigeration / RAC
~14 min
Paths A–D

Ice Machine Not Making Ice

Ice machine is running but producing little or no ice. Bin is nearly empty.

Unlock with Paths A–D →
Commercial Refrigeration / RAC
~10 min
Paths A–D

Reach-in / Prep Table Not Holding Temperature

Prep-table reach-in is warm. Product in the pan rail is above safe temperature.

Unlock with Paths A–D →
Commercial Refrigeration / RAC
~15 min
Paths A–D

Walk-in Freezer Defrost Fault

Walk-in freezer keeps icing up. Product temperature climbs a few degrees each day and the customer has been scraping the coil by hand.

Unlock with Paths A–D →
Commercial Refrigeration / RAC
~11 min
Paths A–D

Natural Refrigerant Safe-Handling Decision

You are called to a small commercial site that has a new hydrocarbon (R-290) reach-in and a CO₂ (R-744) system in the same building. You must decide safe working practice before starting diagnosis.

Unlock with Paths A–D →
Commercial HVAC / RTU
~15 min
Free

Rooftop Unit Not Cooling

Retail space is warm. Thermostat is calling for cooling, the supply fan runs, but the air out of the diffusers is not cold.

Start the free lab →
Commercial HVAC / RTU
~13 min
Paths A–D

RTU Economizer Stuck — No Free Cooling

Rooftop unit is cooling, but energy use is high and the economizer never seems to bring in outdoor air even on mild days.

Unlock with Paths A–D →
Commercial HVAC / RTU
~15 min
Paths A–D

RTU High Static — Low Airflow and Poor Cooling

Retail space is warm at the back of the building. The RTU runs constantly and the store manager says the vents 'barely blow'.

Unlock with Paths A–D →
Commercial HVAC / RTU
~13 min
Paths A–D

RTU Gas Heat — No Heat / Ignition Fault

Rooftop unit is not heating. Thermostat is calling for heat. Blower may run, but there is no useful heat from the supply.

Unlock with Paths A–D →
Installation, Start-up & Commissioning
~14 min
Paths A–D

RTU First Start-up Sequence

New packaged RTU has been set on the curb. Electrical and duct connections are complete. You are called to perform first start-up and basic verification before handover.

Unlock with Paths A–D →
Residential HVAC Service & Diagnostics
~12 min
Free

No Cool, First Call — Work the Order

“It stopped cooling sometime yesterday. The fan blows but the air is room temperature.”

Start the free lab →
Residential HVAC Service & Diagnostics
~13 min
Paths A–D

Running But Only 8°F Split

“It runs all day and the house never really gets cold. It used to shut off by lunchtime.”

Unlock with Paths A–D →
Residential HVAC Service & Diagnostics
~12 min
Paths A–D

28°F Split, Weak Air at the Registers

“The air coming out is freezing but the bedrooms never cool down.”

Unlock with Paths A–D →
Residential HVAC Service & Diagnostics
~13 min
Paths A–D

Condenser Dead, Indoor Blower Running

“The inside fan runs but the box outside never comes on anymore.”

Unlock with Paths A–D →
Residential HVAC Service & Diagnostics
~14 min
Paths A–D

Ice on the Suction Line, Filter Black

“There is ice all over the copper at the outdoor unit and water dripping in the closet.”

Unlock with Paths A–D →
Residential HVAC Service & Diagnostics
~13 min
Paths A–D

Short-Cycling After a Capacitor Swap

“Another company put a capacitor in last week. Now it starts, runs a minute, and clicks off.”

Unlock with Paths A–D →
Residential HVAC Service & Diagnostics
~15 min
Paths A–D

Heat Pump Running on Strip Heat Only

“The house stays warm but the electric bill doubled. The little heater light is on all the time.”

Unlock with Paths A–D →
Residential HVAC Service & Diagnostics
~15 min
Free

Inverter Mini-Split (R-32) Will Not Pull the Room Down

“The head runs all the time but the office sits at 28°C. It was fine last summer.”

Start the free lab →
Commercial HVAC / RTU
~16 min
Paths A–D

Communicating RTU — No Cool, No Fault Code

“The front half of the store is warm. The unit says everything is normal on the display.”

Unlock with Paths A–D →
Commercial HVAC / RTU
~16 min
Paths A–D

Occupied Retail, Warm Air, “The Last Tech Said It Was Fine”

“Two techs have been out. Both said it is working correctly. My staff are standing in 29°C.”

Unlock with Paths A–D →
Full Systems
~14 min
Paths A–D

Leak Smell on a Current-Refrigerant System

“There is a sharp smell in the plant room and the unit keeps tripping. Can you just braze it up today?”

Unlock with Paths A–D →
Installation, Start-up & Commissioning
~15 min
Paths A–D

Commissioning Day — Drawings Versus As-Built

“We need the start-up sheet signed today so the fit-out can hand over.”

Unlock with Paths A–D →

Related free guides